skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


Search for: All records

Creators/Authors contains: "Rollins, Hannah"

Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher. Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?

Some links on this page may take you to non-federal websites. Their policies may differ from this site.

  1. Abstract In tissue engineering, once a scaffold has completed mechanical property testing, it must then undergo biological characterization which determines if the scaffold is capable of supporting cell viability. To perform biological tests, cells must be seeded onto a scaffold with the help of bioreactors, the four main types being: (i) rotating wall, (ii) spinner flask, (iii) compression, and (iv) perfusion bioreactor. In perfusion bioreactors, a consistent flow of material is introduced (using a pump) into the inlet of the bioreactor chamber where multiple scaffolds of a disc geometry are located. However, the intrinsic, complex interaction between the scaffolds and material flow as it goes through the bioreactor chamber affects the viability of the seeded stem cells. Therefore, there is a need to identify consequential fluid dynamics phenomena governing the material flow in a perfusion bioreactor. In this study, using a CFD model, the effects of critical scaffold parameters (such as the number of scaffolds, scaffold diameter, scaffold thickness, and number of pores) on the main flow properties (i.e., flow pressure, wall shear stress, and streamline velocity) influential in cell proliferation and bone development will be investigated. It was observed that increasing the number of pores, in addition to decreasing the pore diameter had an adverse effect on the maximum forces occurring on the scaffold. In addition, changing the overall scaffold diameter did not appear to have as much as an effect as the other parameters. Furthermore, it was observed that a decrease in porosity would lead to an increase in wall shear stress and consequently in cell death. Overall, the outcomes of this study pave the way for optimal design, fabrication, and preparation of cell-laden bone scaffolds for treatment of bone fractures in clinical settings. 
    more » « less
    Free, publicly-accessible full text available November 17, 2025